. 7. Richmond, TXThe water pump also forces hot coolant through the heater core during the cooling system’s cycle. It was working good enough after he added more freon. I have a 94 Ford Escort Wagon, 1. The owners manual shows it directly above the fuse box, but it isn't. Registered. If one of the hoses is hot, and the other one is cold, that is a pretty good indication that the heater core is clogged. 1994 Ford Escort LX Wagon 1. I could hear the blower going but the doors that control the direction of the airflow would close. 99 escort wagon 2. 9 turns over but won’t start - So I’m at my wits end with this car. 191 below average station wagon 141,744 gasoline blue. 1997 Ford E-350 7. 1999 Ford Escort: wagon. 3. A plugged/clogged heater core. unplug the relay and check for power coming to the relay i think the one on the left is the low. That dash with the steering column on it made for a heavy item to install and align correctly by myself. 1993 ford E350 club wagon has no air conditioning heater or blowing air. After a few minutes, the air conditioner trips a breaker or blows a fuse. Test the fan motor(s) by applying 12 power directly. Amedee. The air and heat, etc. It would seam the switch in the dash is not working. 677 posts · Joined 2005. So it depends; If you seal them you are subject to an “air tight(ish) interior. Access quick reference guides, a roadside assistance card, and supplemental information if available. 9 lt engine. replaced thermostat,heater core and still no heat. Replace the motor if it's damaged. Also when I turn on the heat it does not warm up much, but the blower is. The most common causes for AC blowing hot air in Ford F-150 are low or overcharged refrigerant, compressor malfunction, dirty condenser or evaporator coils, faulty blend door actuator, defective evaporator temperature sensor, bad AC pressure sensor, and bad fuse or relay. wipers. 1. HELP!!!! I have a 95 escort wagon with 1. I have a 1999 Ford Escort wagon. The valves in your heater core open to let warm air into the vehicle. Just no air making it inside the cab. [The price is skyrocketing, I've paid $27, $38, and last year $52 for a replacement switch. One should have +12V. Received 15 Likes on 12 Posts. Disappears when up to speed. I tried hitting buttons and cycling power for about 10 minutes. thank you. Most systems are designed to blow very cold air, between 32 and 40 degrees! These cooling coils, called the evaporator, is where the actual cooling of the air happens. Mode and blend doors appear to be functioning properly. In this video we're looking at an easy fix for the reason your vents aren't blowing air. blower motor. Signs of a Blown Head Gasket: White smoke from the tail pipe. If the condenser fan motor is not working properly, the refrigerator won’t cool properly. The heater may stop working in Ford Focus due to low coolant level or air in the cooling system, clogged heater core, bad thermostat, faulty blend door actuator, bad water pump, dirty cabin air filter, bad blower motor, or HVAC control unit malfunction. 1. Anytime the heater fan is on, the radiator fan runs at low speed, and the air conditioning pump is activated. Questions / Ford / Escort / 1994 / cooling fan relay location ? Cooling fan relay location ? 1994 Ford Escort. 1 ohms. this gives the blower motor some current to create positive ventlation . I assume it is stuck in the off position and not opening up the air flow. A sturdy water bottle like a Nalgene should work fine as well. Suddenly coolant was leaking but not much. driving home from work and. 9 engine 1. I have a 94 Ford Escort Wagon, 1. Vocational, Technical or Tra. Hi, The most likely problem is either blower motor relay or blower motor. Plug in a new one purchased from your Ford parts dealer. where is the cooling fan thermostat located on the 94 escort 1. 99 escort wagon 2. 4. the heater stopped blowing. Vent blows heated air. com. The “on” setting causes the fan to run constantly, and unheated air will blow from the vents between heating cycles. when the ac is running the egine overheats,when you turn off the ac it returns to normal operating temp. full of freon. Today, while I was driving with the AC on, the fan suddenly made what I can only describe as a loud muffled rattling noise with a pretty stout vibration. Note: Dirty cabin air filter mostly only leads to reduced cooling. We have a 94 ford escort wagon that died when it stopped at a stop sign. Blown fuse. AC Only Blows Warm Air in Ram Truck -. Even while driving-no codes-if the. all two cases car starts. The door connection to the arm is the problem. block. Tim. but the same problem persists, with it. The a/c blows cold for about 20 minutes and then starts blowing. ”. 1,695 1994 Ford Escort - Independence, OR. cooling fan does not operate. Average failure mileage is 117,500 miles. Test your blower motor’s connections. Fuse box diagrams (location and assignment of electrical fuses and relays) Ford E-Series / Econoline / Club Wagon / Van (1992, 1993, 1994, 1995, 1996). 27,894 satisfied customers. my 97 tbird lx v8 has an intermittent interior blower fan. 10 minutes shy of 2 hours to reinstall dash and components. Overall circuit protection (Charging System, BTN, Cooling Fan, Fuel Pump, OBD-II, ABS Fuses, Ignition Switch, Headlamps) BTN: 40A* Coupe: Hazard, Stop, Door lock, Tail, Room and Horn fuses of the I/P fuse panel Sedan: Hazard: ABS: 60A* Anti-lock Brake System (ABS) main relay: COOLING FAN: 40A* Constant control relay module (cooling fan). They both should feel warm or hot to the touch with the engine on. 0 6cylinder. Everything on the dash still works just fine. AM/FM. IT trickles out faster the faster I drive, but it seems the fan is not working. Main 60a fuse good. Fan speed works great. In addition to cooling, freon lubricates the compressor when it runs. This problem can also occur if your vehicle has a faulty relay; the relay helps to. What causes the radiator blower fan fuse to blow? It's becauseof a failing radiator blower motor, If that's the case have the radiator blowerfan motor replaced. read more 1,695 1994 Ford Escort - Independence, OR. the heater stopped blowing. The most recently reported issues are listed below. 8l engine)), engine controls, instrument cluster (manual transaxle only), intrument panel fuse panel (cigar, defrost, engine ABS, heater, HEGO (1. 27,894 satisfied customers. The coolant sensor tells the computer, which turns on a relay, which turns on the fan. I have the EXACT symptoms this guy had. Turn on the fan, and inspect if the fan is rotating counterclockwise. BigBob. 7. One of the first symptoms commonly associated with a bad or failing cooling fan relay is an engine that runs hot or overheats. The round gear is located on drivers side, under dash, about mid lower leg area. you turn on the low speed blower relay. If ok, look for blown fan fuse or faulty fan relay. The outside exhaust fan continued running and I noticed the freon line was iced over. my 1997 ford escort wagon not getting any power at all to the cooling fan,i tried to jump it and that will not work i tested the wires with a test light and there is no power. Less common causes are clogged expansion valve or orifice tube. I have a 1993 escort wagon with 1. check to see if getting power and if you are getting power then replace fan motor The gear shift of my '94 Escort Wagon won't move out of park. 1996 escort: blowing hot air. My 1998 ford escort keeps blowing the 40amp fuse in the engine fuse box. I found this on Repairpal Common problems page for you 97 ford escort. Top 10 Reasons that your Car AC isn’t Cooling Enough. If you have 12v at harness connector then the blower motor is defective. If the fan is only working intermittently, you could notice that warm air only blows out occasionally. This cools down the air before it gets blown out of the ventilation system into your car to keep you comfortable. When you press the AC button, you can hear. It will start and if you press the accerator to about 2000rpm's the engine will. Unplug the defective control. 1999 Ford Escort: wagon. 1999 Ford Escort 4 Dr SE Wagon-Maintenance & Repair. Check for any blown fuses or a tripping breaker. blower motor resistor ?? since there is no air blowing at all, I assume it has nothing to do with resistor. Mercedes E320, 2000, wagon, A/C blower ,just stopped blowing. 9) went on after transmission work. 9L My problem is my engine was running Hot while Idle and cold while driving (Looking at the gauge on the dash). When the AC stops cooling, tap the face of the compressor clutch with a screwdriver handle. 5. The heat normally comes from the hot coolant. air,cruise, 5spd. When your floor fan stops working, don’t panic! If you follow these troubleshooting steps to make sure your electrical connections are good and that your fan is basically clean and well lubricated, you may be able to get it back up and running on your own. Engineered for interior of van air out only, by removing them you defeat that system. 94 Ford Club Wagon fan for air cond stopped working 94 Ford Club Wagon blower for the heating and airconditioning - Ford 1994 Club XLT question. licensed residential contract. Not hot air, not cold air, no air, no sound, nothing no matter what position the dials are turned in. What are the reasons? my list: 1. If you find that the fan stops running immediately, the issue lies with the sensor. If your test proves incoming power, replace the fan motor. I have replaced the motor with a new unit. Locate and remove the horn fuse, or the horn relay. I typed in 1993 escort fan not working and this came up. Defrost vents seem to be more restricted than others flowing almost no air at all. 0 Zetec - 5 speed manual Heater fan was only blowing on 4 a few weeks ago. The fan for my heater/AC has stopped blowing. This issue has nothing to do with cold air coming out instead of heat. Be the first to answer Jul 07, 2014 • 1994 Ford Escort. Joined Jun 27, 2015. 5,821 satisfied customers. For this, You can operate and regulate cabin temperature according to your preference. If your find a circuit blown fuse or tripped breaker, the fan motor might be pulling too much voltage, causing the fault. when engine temp rises. 9L. Associate Degree. It controls the flow of outside air in and out of the charcoal canister. Check as well for leaks in the hose or the engine. replaced the radiator, idle air control. I am very happy with the van and engine except that the rear ac does not work and only throws hot air out of the floor vents. front air. Over time, the lubricant. I bought a 1997 E350 Club Wagon with the 7. Local Auto Zone had part. A faulty cooling fan relay can also negatively affect air conditioning (A/C) performance. The AC clutch does not engage. If the neither hose has any heat, you may have air in the cooling system, low fluid, or low pressure. when a fuse keeps blowing it can only be one of two causes. Overheated engine. Most cars have two cooling fans, one for the condenser and the other for the radiator. I am assuming it is a fuse, but can't find the one for the fan. Salem, OR at freeclassifieds. Fan Blower won't work. Less common causes are dirty or sluggish blower motor and faulty mode door actuator.